Your position: Home > volume or frequency control > kit-volume

1 kit for water vending machine volume control with JY926 multi coin acceptor button start and pause acceptor multi coins

Item Code: 32744724886
Sold: 0
SKU:
32744724886
    Please select the information you wantX
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
+
-
Units 2500 in Stock
  • Description
Specifications

product

 

 

 

DESCRIPTION

 Multi coin acceptor

  DSC08041

 

DSC08043

DSC08044

DSC08045

DSC08046

DSC08047

 

DESCRIPTION

  •  Intelligent CPU software control, and high accuracy
  • Self-programming without PC, and automatic self-test for proble
  •  Accept different kinds of coins at the same time. Free to set up pulses' output
  •  Prevent not only electric shock but also electromagnetic interference
  • Support multi coins with only 1 signal output
  • Capable of accepting all worldwide Coins and Token

CONNECTIONA AND SWITCHES

English

SETTING FOR COINS

  1. Hold on the button"ADD" and the button "MINUS" simultaneously for seconds,then letter "A" will appear from the LED display.
  2. Hold on the button "SET" for seconds, and letter "E" will appear. Next, use the button "ADD" and the button "MINUS" to choose how many kinds of coins you would like to use. Next, hold on the button "SET" for seconds to finish.
  3. Letter "H1" will appear. Use the button "ADD" and the button "MINUS" to choose how many samples you would like to insert later. Next, hold on the button "SET" for seconds to finish.
    The maximum is 30. Please choose more than 15 samples for more accurate.
  4. Letter "P1" will appear. Use the button "ADD" and the button "MINUS" to choose the amount of output's signals/pulses for coins. Next, hold on the button "SET" for seconds to finish. 
    The maximum pulse is 50.
  5. Letter "F1" will appear. Use the button "ADD" and the button "MINUS" to choose accuracy. Next, hold on the button "SET" for seconds to finish.
    The value is from 1 to 30, and 1 is the most accurate. Normally,5-10 is fine. If kinds of coins are too similarthe value should be more accurate.
  6. The first kind of coin has been set up so far. Please repeat No.3- No.5 until all kinds of coins has been set up. Letter "A" will appear again after all above procedures is finished.
  7. Hold on the button " SET" for seconds, and letter "E" will appear. Finally, turn off and turn on the power. The setting will be saved.

Sampling FOR COINS

You can start sampling after the setting is finishedPlease choose more than 15 coins. The sampling will affect the accuracy of coin selector.

----------------------------------------------------------------------------------------------------

  1.  Hold on the button "SET" for seconds, then letter "A1" will appear from the LED display.
  2. Please start to sample the first kind of coins. The letter "A1" will appear again after finished.
  3. Hold on the button "SET" for seconds, then letter "A2" will appear. Next, please start to sample second kind of coins. The letter "A2" will appear again after finished.
  4. Please repeat No.3 until all kinds of coins you need is set up.
    If you already set up all kinds of coins you needand it is less than the product hasplease turn off powerFor exampleIf you choose "6-kind-of-coin of multi-coin selector" to set up 4 types of coins, please turn off power after you see second “A4”.
  5. The system will restart automatically after finished.
  6. The product can be used after finishing sampling.

AP MODE

  • Using this mode, you are able to control the output pulse ratios.
    For example: 2 coins for 1 pulse or 3 coins for 1 pulse.
  • If you don't need to use AP mode, please skip AP mode setting.
    -----------------------------------------------------------------------------------------------

SETTING FOR AP MODE

  1.  Please hold on the button "SET" and the button "ADD" simultaneously for seconds, then hold on the button "SET" for seconds to get into AP mode
  2. Please select the value of AP mode. The coin selector will generate 1 external signal output when the internal signal- "P" value of parameter- reaches the value
  3. The default value of AP mode is 1.

 

size

10

 

note

  • Please note this auction is for MODEL JY-92X OR JY-92XA
  • For following coins, we can pre-program coins for you if order more than 10 pcs. 
  • Please check following TABLE for MODEL you will receive
    92X
     
  • Other currancy, please feel free to contact us or we pick up to you based on country

 Control board

 

 

 

HTB13jGRhScqBKNjSZFgq6x_kXXaN

HTB13jGRhScqBKNjSZFgq6x_kXXaNHTB1cng3v_lYBeNjSszcq6zwhFXaz

Connection and Position

DSC07717_

1: Display       2: White lead      3: Pause for mode 01:02

4: Flow sensor No.11 input signal reach MAX LIMIT                    

5: Output: Control first solenoid valve   
6: Output: Control second solenoid valve

7: Input devices-coin acceptor, bill acceptor, or card reader:

    YELLOW: DC12V, WHITE: input signal, BLACK: GND

8: AC jack-5.5mm*2.1mm       

9: Flow sensor No.10 input signal reach MAX LIMIT

10: Input: from flow sensor No.6      

11: Input: from flow sensor No.5 

12: button START for MODE 01:02    

13-16: Button S4, S3, S2, and S1

NOTE: Free to connect DC12V to either No.8 or No.9.

             Please reference to attached 2 for connection example

 


 

Setting

12

CODE

VALUE

Function

CODE

VALUE

Function

01

01

Start instantly

05

01-99

tens and units FLOW SENSOR SIGNAL INPUT for 1 cost on No.5

01

02

Start by pushing button

06

00-30

Thousands and hundreds FLOW SENSOR SIGNAL INPUT for 1 cost on No.5

02

01-99

Cost for working device on No.5

07

00-99

tens and units MAX SIGNAL INPUT from flow sensor to No.11

03

01-99

Cost for working device on No.6

08

00-30

Thousands and hundreds MAX SIGNAL INPUT from flow sensor to No.11

04

01

Non-memory

09

01-99

tens and units FLOW SENSOR SIGNAL INPUT for 1 cost on No.6

04

02

memory

10

00-30

Thousands and hundreds FLOW SENSOR SIGNAL INPUT for 1 cost on No.6

Note:

Function is not active:

Set both code 07 and 08 as 00.

Set both code 11 and 12 as 00.

11

00-99

tens and units MAX SIGNAL INPUT from flow sensor to No.10

12

00-30

Thousands and hundreds MAX SIGNAL INPUT from flow sensor to No.10


 